RCD Installation Requirements – What Homeowners Need to Know
Understanding your RCD (Safety Switch) obligations is essential for keeping your home safe and compliant with WA regulations.
For homes built after 1 January 2019
All electrical installations completed after 1 January 2019 must comply with AS/NZS 3000:2018 (Wiring Rules).
This means:
- All final sub-circuits must be RCD protected
- This includes circuits supplying hard-wired appliances such as:
- Stoves
- Air-conditioners
- Hot water systems
In new homes, full RCD coverage is mandatory.
For homes being sold, rented, or hired
Under the Electricity Regulations 1947, any residential property that is:
- Sold
- Rented
- Hired
- Used as short-term accommodation
must have:
- At least two RCDs installed
- Protecting socket outlets and lighting circuits
- No more than three final sub-circuits per RCD
- If there are multiple lighting circuits, they must be split across both RCDs
Important to note:
- The law does not require RCDs on hard-wired appliance circuits for sale or rental compliance
- Homes built before 1 January 2019 are not required to upgrade all circuits, unless the owner chooses to
For property compliance checks
If an electrician is engaged to verify RCD compliance for a sale or rental, the installation must meet the Electricity Regulations 1947 — not the newer Wiring Rules.
Testing Your RCDs
To ensure your RCDs continue to provide effective protection, they should be tested regularly to confirm they are operating correctly.
If your switchboard is in good condition and you feel comfortable doing so:
- Open the meter box
- Press the “Test” (T) button on each RCD
- The switch should trip immediately to the OFF position
If the RCD does not trip straight away, or will not reset to the ON position, you should contact a licensed electrical contractor as soon as possible.
Testing should be carried out:
- In accordance with the manufacturer’s instructions, or
- At least every three months, whichever is more frequent
Locating the Test Button
The test button is marked with a “T” and is located on the front of the RCD.
The button may vary in:
- Shape
- Colour
- Size
However, it will always be clearly identified by the T marking.
Some examples are shown in this handy guide.
If you are unsure how to test your RCDs or would prefer a professional inspection, Gen Y Electrical can test and assess your RCD protection for you.
Important Update – Type AC RCDs No Longer Permitted
From 30 April 2023, Type AC RCDs must no longer be installed in Australia.
Under AS/NZS 3000:2018, any new work and any Notice of Completion submitted after this date must use Type A RCDs.
If you’re unsure whether your switchboard is compliant, Gen Y Electrical can inspect, upgrade, and certify your RCD protection to keep your property safe and legal.
Contact Gen Y Electrical for professional advice and compliance checks.